Product Details:
Place of Origin: China
Brand Name: Perkins
Certification: ISO9001:2008, CE
Model Number: GNRP
Engine: Perkins
Alternator: Stamford, Leroy somer ,Marathon
Control Panel: Smartgen, Deepsea,ComAp
Rated Power: 15 kva
Rated RPM: 1500rpm or 1800rpm
Frequency: 50Hz or 60Hz
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiable
Delivery Time: within 15 days
Payment Terms: T/T, L/C, Western Union, Western Union, MoneyGram
Detailed Product Description
High Light:

perkins generator set

,

silent diesel generator

silent 15 kva 3 phase perkins diesel generator 11kw power manual control panel

 

The Perkins diesel generator set adopt integrative structure, engine is fix on high strength steel basic frame, anti vibration instrument between the engine and basic frame, cooling fan have protecting cap, control cabinet and circuit breaker installed on Gen-set .

 

generator 15kva specification:

 

Set Model GNR15
Prime at 50HZ, 40°C ambient 12KW 15KVA
Standby at 50HZ, 40°C ambient 13KW 16.5KVA
Rated Gen-set output 230/400V 50Hz
Rated Relative humidity ≤ 60 %
Dimension (L×W×H) 1500×650×1050mm
Weight 450kg
Fuel consumption 100% prime load 5,4 l/hr
Structure of Gen-set The Gen-set adopt integrative structure, engine is fix on high strength steel basic frame, anti vibration instrument between the engine and basic frame, cooling fan have protecting cap, control cabinet and circuit breaker installed on Gen-set
Control system (Optional) Basic control panel or Advanced control panel with automatically start-up function and other function

 

engine 404D-22G specification:

 

Engine Brand Perkins 
Engine Model 404D-22G
Governor/Class Mechanical
Cylinder NO. 4
Engine build Vertical in-line
Fuel spray pattern Indirect injection
Aspiration Naturally
Cooling mode Radiator cooled (enclose water)
Bore and stroke 84×100mm
Compression ratio 23·3 : 1
Displacement 2.216L
Engine Prime Power at 1500rpm 18.4KWm
Engine Standby Power at 1500rpm 20.3KWm
Start-up mode 12V, electric
Starting/Min temperature /
Lubricating oil consumption Lubricating oil consumption less than 10% Fuel consumption
Lubrication oil capacity 10,6 litres
Coolant capacity – radiator and engine (40°C) 6,98 litres
Exhaust temp – full load prime 445°C
Exhaust gas flow – full load prime 3,64m³/min
Exhaust gas back pressure max 10,2 kPa
Air flow – radiator (40°C ambient) /
Air intake – engine– full load prime 1,45m³/min
Standard Air intake temp 25°C
Fuel type #0 Diesel (Natural temperature)
Filter system Adopt whole changeable lubricating oil, fuel filter and air filter
Exhaust system Adopt industrial high efficiency silencer and flexible bellows
Engine derating – altitude Above the sea-level 1525m high, a fall of 4% from a rise of 300m.

 

The specification of alternator:

 

Brand

Stamford,marathon, leroy somer.ect

Regulator

AVR automatic voltage regulating

Excite type

pret or shunt

Connecting type

3PH star, 3PH-DELTA

Steady frequency change

0-5%

No load voltage

95%-105

Steady voltage

±1

Insulation degree

H degree

Exclosure degree

IP23

Control Panel:

 

1. Key switch (manual type) control panel

Shock resist is fitted between control panel and generator set. Loose sheet is also fitted.The equipments of control panel are Meters with Voltmeter,Ammeter,Frequency list,Water thermometer,Oil pressure gauge,Hour meter.

2. Control parts

Start/stop key switch, start button, emergency stop button, voltage regulation

resistance, speed regulation resistance. Voltage phase switch ,Electric current phase selecting switch.

3. Protection setting for engine

For emergency shut down, overfeed, high water temperature, low oil pressure. ATS switch is optional components when some accidents appear, The digital Protector can shut dow

 

Control system:


1) Automatic alarm system: the unit has the acousto-optics alarm system and
arrestor for any situation asthe start defeat, the water is over temperature, the oil
pulls down, over speed, over load and over current.
2) Operation display:
a) Unit voltage, tri-phase load current and frequency display
b) Water temperature, oil pressure display
c) Fuel level, fuel temperature display
d) Audible and visual alarm lamps and buzzers

 

 

 

Standard information:

1).Type:open/soundproof/weatherproof/trailer/container type

2). Rated voltage:220/380V,230/400V,240/415V,120/240V
3). Power factor:0.8
4). output type:AC three phase

5). Motor:brushless

6). Starting method:12/24DC electric starting

7). Governor system: electrical or mechanical governor
8). Short circuit protection: MCCB air switch

 