Dual Redundant N+1 Reefer Container Genset 2x400kVA with Motorised ATS Container Generator Set

I'm Online Chat Now

Dual Redundant N+1 Reefer Container Genset 2x400kVA with Motorised ATS Container Generator Set

Dual Redundant N+1 Reefer Container Genset 2x400kVA with Motorised ATS Container Generator Set
Dual Redundant N+1 Reefer Container Genset 2x400kVA with Motorised ATS Container Generator Set Dual Redundant N+1 Reefer Container Genset 2x400kVA with Motorised ATS Container Generator Set Dual Redundant N+1 Reefer Container Genset 2x400kVA with Motorised ATS Container Generator Set

Large Image :  Dual Redundant N+1 Reefer Container Genset 2x400kVA with Motorised ATS Container Generator Set

Product Details:
Place of Origin: China
Brand Name: Perkins
Certification: ISO9001:2008, CE
Model Number: CRP400D
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: USD$88000 to USD$135000
Packaging Details: Wooden package
Delivery Time: within 30 days
Payment Terms: T/T,L/C,Western Union,
Supply Ability: 40 units / month
Detailed Product Description
Model: CRP400D Configuration: 2 X 400kVA N+1 Redundant
Changeover: Motorised ATS, Under 10s Voltage: 460V , 60Hz
Reefer Sockets: 80pcs Split Across Modules Fuel Tank: 2 X 1500L
Cooling System: Water Cooling Noise Level: 65dBA At 7m
Color: Blue
Highlight:

dual redundant reefer genset

,

n+1 container power redundancy

,

auto transfer switch genset

Cold chain contracts do not tolerate a single point of failure. This redundant power pack places two independent Perkins diesel generator modules on one skid, each with its own alternator, control panel and fuel circuit, tied together through a motorised changeover panel. Under normal duty one module carries the full reefer socket load while the second stands in hot standby; on a fault, under voltage or over temperature trip, the ATS transfers the load in under 10 seconds so the reefer compressors never see a sustained outage. Both modules can also run in parallel for peak pull-down after a container loading surge.

Redundant Architecture
  • Two independent Perkins diesel gensets, 400kVA each, mounted on a common skid
  • N+1 duty: one module online, one module hot standby at all times
  • Motorised ATS with mechanical and electrical interlock, no parallel fault path
  • Transfer time under 10 seconds on mains or module failure
  • Manual bypass handle for maintenance without dropping the reefer load
Paralleling and Load Management
  • Optional synchronising controller for parallel operation during pull-down peaks
  • Load sharing within ±5% between modules in parallel mode
  • Reverse power, over current and earth fault protection on each module
  • Non-essential load shedding contact for compressor start current surges
  • Reefer socket boards split across both modules for physical segregation
Engine and Alternator
  • Perkins 6-cylinder turbocharged water-cooled engine, electronic governor
  • Brushless alternator, 4 pole, IP23, Class H insulation, AVR ≤±1%
  • 460V / 60Hz three-phase output matched to North American reefer machinery
  • Independent 1500 L fuel tank per module with cross-connect valve
  • Radiator sized for 45°C ambient and continuous terminal duty
Monitoring and Alarms
  • Common control cubicle showing live status of both modules and ATS position
  • Alarm transfer to standby on low oil pressure, over temperature or over speed
  • Event log for changeover history and run hours per module
  • Remote dry contacts for terminal SCADA and CCTV room integration
  • Battery charger and dual battery bank per module
Terminal Grade Build
  • Stainless steel canopy with acoustic lining, 65 dBA at 7 m
  • Heavy-duty skid with forklift pockets and four-point lifting lugs
  • Anti-vibration mounts isolating both modules from the container floor
  • Full side access for injector, filter and breaker maintenance
  • 15 months or 1200 running hours warranty, ISO and CE certificated
Technical Specifications
Model CRP400D
Configuration 2 x 400kVA, N+1 redundant
Changeover Motorised ATS, transfer under 10 s
Rated Output 460V / 60Hz / 3 phase
Fuel Tank 2 x 1500 L with cross connect
Reefer Sockets 80 outlets split across both modules
Noise Level 65 dBA at 7 m